Extra Flex 15-16 O.R. 15 PETP-PUR 16 PVC-PVC
Type |
Code | Formation | Ext.Diam mm | CU-weight kg/km |
15 | 15H9MXC | 9x0.50 | 8.8 (+/-0.3) | 72 |
16 | 16H9MXC | 9x0.50 | 9.8 (+/-0.3) | 72 |
APPLICATION :
Data transmission, Indramat tachymetric connection, Dynamic applications, Robotics.
TECHNICAL CHARACTERISTICS :
Service Voltage :
250V
Test Voltage :
1500V
Insulation Resistance :
>/= 100 Mohm x km (at 20oC)
Temperature :
service from -10oC to + 80oC storage from -30oC to + 80oC
Conductor Stranding :
extra-flexible class 6 acc. Standards VDE 0295 - IEC 228 - CEI 20-29
Primary Insulation :
PETP polyester terephtalate for type 15Special PVC compound for type 16
Conductors Identification :
GRN - BR - GRY - YE - BLK - BL - RD - WHT - PK
EMC Shield :
tinned copper braid covering >/= 85%
Taping :
special tape
Jacket :
PUR compound abrasion-free for type >15 special PVC compound for type 16colour orange RAL 2003
Min. Bending Radius :
90mm
Translation Speed :
180m/min. for type 15, 120m/min for type 16
Max. Acceleration :
7m/s2 for type 15, 4m/s2 for type 16
Reference Standards :
VDE 0472-804B-IEC 332.1-CEI 20-35for flame resistance for 15 type VDE 0472-804-C - IEC 332.3A - CEI 20-22 IIfor flame resistance for 16 typeVDE 0472-803-B for ASTM2 oil resistanceCNOMO E.03.40.150N - NFT 46-013 for resistance to industrial oilsUL-CSA upon request for 16 type.